Electrical, Specialty Fuses
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
KLKD012.TFUSE CARTRIDGE 12A 600VAC/VDC |
77 |
|
Datasheet | POWR-GARD® KLKD | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 12A | 600 VAC | 600 VDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, CSA, UL, VDE | - | 100kA AC, 50kA DC | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
SPXV001.T1500VDC 1 AMP PHOTOVOLTAIC FUSE |
56 |
|
Datasheet | POWR-GARD® SPXV | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 1A | - | 1.5 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, gPV, UL | - | 50kA | 0.406" Dia x 3.333" L (10.30mm x 84.65mm) | - | - |
|
|
KLKD004.HXRFUSE CARTRIDGE 4A 600VAC/VDC |
37 |
|
Datasheet | POWR-GARD® KLKD | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 4A | 600 VAC | 600 VDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, CSA, UL, VDE | - | 100kA AC, 50kA DC | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
|
KLKD004.TFUSE CARTRIDGE 4A 600VAC/VDC |
29 |
|
Datasheet | POWR-GARD® KLKD | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 4A | 600 VAC | 600 VDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, CSA, UL, VDE | - | 100kA AC, 50kA DC | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
SPXV002.T1500VDC 2 AMP PHOTOVOLTAIC FUSE |
21 |
|
Datasheet | POWR-GARD® SPXV | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 2A | - | 1.5 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, gPV, UL | - | 50kA | 0.406" Dia x 3.333" L (10.30mm x 84.65mm) | - | - |
|
|
KLKD02.5TFUSE CARTRIDGE 2.5A 600VAC/VDC |
19 |
|
Datasheet | POWR-GARD® KLKD | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 2.5A | 600 VAC | 600 VDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, CSA, UL, VDE | - | 100kA AC, 50kA DC | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
|
KLKD007.TFUSE CARTRIDGE 7A 600VAC/VDC |
17 |
|
Datasheet | POWR-GARD® KLKD | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 7A | 600 VAC | 600 VDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, CSA, UL, VDE | - | 100kA AC, 50kA DC | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
|
KLKD008.TFUSE CARTRIDGE 8A 600VAC/VDC |
14 |
|
Datasheet | POWR-GARD® KLKD | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 8A | 600 VAC | 600 VDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, CSA, UL, VDE | - | 100kA AC, 50kA DC | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
KLKR012.TFUSE CARTRIDGE 12A 600VAC/300VDC |
24 |
|
Datasheet | POWR-GARD® KLKR | 5AG, 10mm x 38mm (Midget) | Box | Active | Requires Holder | Cartridge | 12A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | CC | CE, CSA, UL | - | 200kA AC, 20kA DC | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
KLKR025.TFUSE CARTRIDGE 25A 600VAC/300VDC |
14 |
|
Datasheet | POWR-GARD® KLKR | 5AG, 10mm x 38mm (Midget) | Box | Active | Requires Holder | Cartridge | 25A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | CC | CE, CSA, UL | - | 200kA AC, 20kA DC | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
CCMR.200TXPFUSE CRTRDGE 200MA 600VAC/250VDC |
20 |
|
Datasheet | POWR-GARD®, POWR-PRO® CCMR | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 200mA | 600 VAC | 250 VDC | Slow Blow | Motor Protection | - | CC | CE, CSA, UL | - | 300kA AC, 20kA DC | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
CCMR.500TXPFUSE CRTRDGE 500MA 600VAC/250VDC |
16 |
|
Datasheet | POWR-GARD®, POWR-PRO® CCMR | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 500mA | 600 VAC | 250 VDC | Slow Blow | Motor Protection | - | CC | CE, CSA, UL | - | 300kA AC, 20kA DC | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
CCMR012.TXPFUSE CARTRIDGE 12A 600VAC/500VDC |
8 |
|
Datasheet | POWR-GARD®, POWR-PRO® CCMR | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 12A | 600 VAC | 500 VDC | Slow Blow | Motor Protection | - | CC | CE, UL | - | 300kA AC, 20kA DC | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
CCMR.250TXPFUSE CRTRDGE 250MA 600VAC/250VDC |
5 |
|
Datasheet | POWR-GARD®, POWR-PRO® CCMR | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 250mA | 600 VAC | 250 VDC | Slow Blow | Motor Protection | - | CC | CE, CSA, UL | - | 300kA AC, 20kA DC | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
JLLN035.TFUSE CARTRIDGE 35A 300VAC/160VDC |
8 |
|
Datasheet | POWR-GARD® JLLN | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 35A | 300 VAC | 160 VDC | Fast Blow | Electrical, Industrial | - | T | CE, CSA, UR | - | 200kA AC, 20kA DC | 0.563" Dia x 0.874" L (14.30mm x 22.20mm) | - | - |
|
0FLQ003.TFUSE CARTRIDGE 3A 500VAC/300VDC |
20 |
|
Datasheet | POWR-GARD® FLQ | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 3A | 500 VAC | 300 VDC | Slow Blow | Transformer Protection | - | - | CSA, UL | - | 10kA | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
0FLQ006.TFUSE CARTRIDGE 6A 500VAC/300VDC |
4 |
|
Datasheet | POWR-GARD® FLQ | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 6A | 500 VAC | 300 VDC | Slow Blow | Transformer Protection | - | - | CSA, UL | - | 10kA | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
0FLQ012.TFUSE CARTRIDGE 12A 500VAC/300VDC |
12 |
|
Datasheet | POWR-GARD® FLQ | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 12A | 500 VAC | 300 VDC | Slow Blow | Transformer Protection | - | - | CSA, UL | - | 10kA | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
0FLQ.500TFUSE CRTRDGE 500MA 500VAC/300VDC |
10 |
|
Datasheet | POWR-GARD® FLQ | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 500mA | 500 VAC | 300 VDC | Slow Blow | Transformer Protection | - | - | CSA, UL | - | 10kA | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
0FLQ.400TFUSE CRTRDGE 400MA 500VAC/300VDC |
10 |
|