Protection Relays & Systems
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Function | Voltage - Supply | Trip Range | Delay Time | Mounting Type | Termination Style | Features | Operating Temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SE-502-01SURGE ARRESTER GDT |
0 |
|
Datasheet | * | Bulk | Obsolete | - | - | - | - | - | - | - | - |
|
SE-703-0T-00MONITOR EARTH LEAKAGE |
0 |
|
Datasheet | SE-703 | Bulk | Active | Ground Fault | 48VDC | 25mA ~ 0.5A | 0 ~ 0.5s | Chassis Mount, DIN Rail | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | - |
|
SE-703-0T-02MONITOR EARTH LEAKAGE |
0 |
|
Datasheet | SE-703 | Bulk | Active | Ground Fault | 48VDC | 25mA ~ 0.5A | 0 ~ 0.5s | Chassis Mount, DIN Rail | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | - |
|
SE-325DNGR MONITOR SUPPLY: 120 VAC/VDC |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault | 120VAC/DC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | - |
|
SE-325ENTNGR MON 240 VAC NON-LATCH GF 0.1 |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 240VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
|
SE-325ESNNGR MON 240 VAC EXT RF NON-LATCH |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 240VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
|
SE-325ESTNGR MON 240 VAC EXT RF GF TIME 0 |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 240VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
|
SE-325NTNGR MON 120 VAC NON-LATCH GF 0.1 |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
|
SE-325SNNGR MON EXTENDED RF TRIP NON-LAT |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
|
SE-325STNGR MON EXTENDED RF TIME GF 0.1- |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
|
SE-105DLGF-GC MON 120VAC/VCD LATCHING GC |
0 |
|
Datasheet | SE-105 | Bulk | Active | Ground Fault | 120VAC/DC | 0.5 ~ 4A | 0.1 ~ 1s | Chassis Mount | Screw Terminal | Automatic Reset, Manual Reset | -40°C ~ 60°C |
|
SE-107DLGF-GC MON UVR LATCHING GC 120V |
0 |
|
Datasheet | SE-107 | Bulk | Active | Ground Fault | 120VAC/DC | 0.5 ~ 4A | 0.1 ~ 1s | Chassis Mount | Screw Terminal | Automatic Reset, Manual Reset | -40°C ~ 60°C |
|
M8100.0170SYNCHROSCOPE |
0 |
|
- |
* | Bulk | Obsolete | - | - | - | - | - | - | - | - |
|
PGR-4300-120GEN GRND FAULT RELAY 120V SUP |
0 |
|
Datasheet | PGR-4300 | Bulk | Active | Ground Fault | 120VAC | 100 ~ 1200A | 0 ~ 1s | Chassis Mount, DIN Rail | Screw Terminal | Manual Reset, Test Button | -10°C ~ 60°C |
|
PGR-4300-12GEN GRND FAULT RELAY 12VDC SUP |
0 |
|
Datasheet | PGR-4300 | Bulk | Active | Ground Fault | 12VDC | 100 ~ 1200A | 0 ~ 1s | Chassis Mount, DIN Rail | Screw Terminal | Manual Reset, Test Button | -10°C ~ 60°C |
|
SE-325DNNGR MONITOR 120 VAC/VDC NON-LATC |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC/DC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
|
SE-325DSNGR MONITOR 120 VAC/VDC EXT RF T |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC/DC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
|
SE-325DTNGR MON 120V GF TIME 0.1 TO 5 S |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC/DC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
|
SE-325ESNTNGR MON 240 VAC EXT RF NL GF 0.1 |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 240VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
|
SE-325SNTNGR MON 120 VAC EXT RF GF TIME 0 |
0 |
|
Datasheet | SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |